Interior WallsInterior wall systems do not typically include wall finishes (i.e. paint, tile, wall covering). However, finishes may be included as a remark designator in tags. Refer to 'Remarks' below.
Exterior wall systems are not tagged in plan or section but described with text in sections and details. Descriptor fromat for walls are: Interior Walls: Int <Category><Hieght>-<Core><Remarks> Rated Assemblies: <Category-Rating><Material><Assembly No> Generic Walls: 0 Generic <Wall Width> |
<Categories>
<Core Size>
Project Browser
Sample Plan
|
<Wall Height>
<Remarks>
Wall TagsWall Tags utilize the 'Type Mark' property of the wall. Rated walls are simply denoted by the UL assembly number or <Hour Rating-Description>. Rated walls are always displayed in color.
ExampleLife Safety Plans at scales 1/8" or smaller use filters to denote rated walls as a single solid color without an outline. View Filters are applied to rated walls using the 'Fire Rating' parameter of walls. A 'View Template' (Life Safety) includes the view filters for rated walls when the template is applied to a view. Doors also contain an instance parameter to match wall types which will provide the wall color continuous through the door in plan view. (Refer to Door page)
|